Supplemental sheets, draft 3

$
0
0

This post updates and replaces the Supplemental sheets, draft 2. It reflects the redesign of the course based on running a prototype version of the course in as a group tutorial in Winter 2013.

Lecture Course

Undergraduate Supplemental Sheet
Information to accompany Request for Course Approval
Sponsoring Agency: Biomolecular Engineering
Course #:
101
Catalog Title: Applied Circuits for Bioengineers

Please answer all of the following questions using a separate sheet for your response.
1. Are you proposing a revision to an existing course? If so give the name, number, and GE designations (if applicable) currently held.

This is not a revision to any existing course.A prototype version of the course was run as BME 194 Group Tutorial in Winter 2013. Notes on the design and daily running of that prototype can be found at https://gasstationwithoutpumps.wordpress.com/circuits-course-table-of-contents

2. In concrete, substantive terms explain how the course will proceed. List the major topics to be covered, preferably by week.

The Applied Circuits course is centered around the labs in the accompanying lab course.  Concepts are taught as needed for the labs, with design and analysis exercises in the lecture course cementing the understanding. The recurring theme throughout the course is voltage dividers: for change of voltage, for current-to-voltage conversion, for high-pass and low-pass RC filters, in Wheatstone bridges, and as feedback circuits in op amp circuits.  The intent of this course is to provide substantial design experience for bioengineering students early in their studies, and to serve both as as bridge course to entice students into the bioelectronics concentration and as a terminal electronics course for those students focussing on other areas.

  1. Basic DC circuit concept review: voltage current, resistance, Kirchhoff’s Laws, Ohm’s Law, voltage divider, notion of a transducer.
    The first week should cover all the concepts needed to do the thermistor lab successfully.
  2. Models of thermistor resistance as a function of temperature. Voltage and current sources, AC vs DC, DC blocking by capacitors, RC time constant, complex numbers, sine waves, RMS voltage, phasors. The second week should cover all the concepts needed to do the electret microphone lab successfully.
  3. Low-pass and high-pass RC filters as voltage dividers, Bode plots. Concepts necessary for properly understanding digitized signals: quantized time, quantized voltage, sampling frequency, Nyquist frequency, aliasing.
  4. Amplifier basics: op amps, AC coupling, gain computation, DC bias for single-power-supply offsets, bias source with unity-gain amplifier.  In the lab, students will design, build, and test a low-gain amplifier (around 5–10 V/V) for audio signals from an electret microphone. We’ll also include a simple current-amplifier model of a bipolar transistor, so that they can increase the current capability of their amplfier.
  5. Op amps with feedback that has complex impedance (frequency-dependent feedback), RC time constants, parallel capacitors, hysteresis, square-wave oscillator using Schmitt triggers, capacitance-output sensors, capacitance-to-frequency conversion.   Topics are selected to support students designing a capacitive touch sensor in the accompanying lab.
  6. Phototransistors and FETs for the tinkering lab and for the class-D amplifier lab. In preparation for the lab in which students model a pair of electrodes as R+(C||R), we will need a variety of both electronics and electrochemistry concepts: variation of parameters with frequency, impedance of capacitors, magnitude of impedance, series and parallel circuits, limitations of R+(C||R) model, and at least a vague understanding of half-cell potentials for the electrode reactions: Ag → Ag+ + e-, Ag+ + Cl- → AgCl, Fe + 2 Cl-→ FeCl2 + 2 e-.
  7. Differential signals, twisted-pair wiring to reduce noise, strain gauge bridges, instrumentation amplifier, DC coupling, multi-stage amplifiers.
    Topics are selected to support the design of a 2-stage amplifier for a piezoresistive pressure sensor in the lab.
  8. System design, comparators, more on FETs. Students will design a class-D power amplifier to implement in the lab.
  9. A little electrophysiology: action potentials, electromyograms, electrocardiograms. Topics are chosen so that students can design a simple 3-wire electrocardiogram (EKG) in the lab.There will also be a bit more development of simple (single-pole) filters.
  10. The last week will be review and special topics requested by the students.

3. Systemwide Senate Regulation 760 specifies that 1 academic credit corresponds to 3 hours of work per week for the student in a 10-week quarter. Please briefly explain how the course will lead to sufficient work with reference to e.g., lectures, sections, amount of homework, field trips, etc. [Please note that if significant changes are proposed to the format of the course after its initial approval, you will need to submit new course approval paperwork to answer this question in light of the new course format.]

The combination of BME101 and BME101L is 7 units (21 hours per week).  The time will be spent approximately as follows:

  • 3.5 hours lecture/discussion
  • 3.5 hours reading background and circuits text
  • 3 hours read lab handouts and doing pre-lab design activities
  • 6 hours lab
  • 5 hours writing design reports for lab

4. Include a complete reading list or its equivalent in other media.

No existing book covers all the material.  For the prototype run of the course, we relied heavily on Wikipedia articles, which turned out to be too dense for many of the students.  Other alternatives (such as Op amps for everyone by Ron Mancini http://www.e-booksdirectory.com/details.php?ebook=1469 Chapters 1–6 and Op Amp Applications Handbook by Analog Devices http://www.analog.com/library/analogDialogue/archives/39-05/op_amp_applications_handbook.html Sections 1-1 and 1-4) were also much too advanced.

In future we will most likely use the free on-line text All about Circuits as the primary text, with material not covered there (such as the various sensors) coming mainly from Wikipedia and the datasheets for the components.

5. State the basis on which evaluation of individual students’ achievements in this course will be made by the instructor (e.g., class participation, examinations, papers, projects).

Students will be evaluated primarily on design reports with some in-class or take-home quizzes to ensure that they do the needed reading on theoretical concepts.

6. List other UCSC courses covering similar material, if known.

EE 101 covers some of the same circuit material, but without the focus on sensors and without instrumentation amps.  It covers linear circuit theory in much more depth and focuses on mathematical analysis of complicated linear circuits, rather than on design with simple circuits.  The expectation for bioengineering students is that those in the bioelectronics track would take BME 101 before taking EE101, and that those in other tracks would take BME 101 as a terminal electronics course providing substantial engineering design.  The extra material in BME 101 would prepare the bioengineering students better for EE 101.

Physics 160 offers a similar level of practical electronics, but focuses on physics applications, rather than on bioengineering applications, and is only offered in alternate years.

7. List expected resource requirements including course support and specialized facilities or equipment for divisional review. (This information must also be reported to the scheduling office each quarter the course is offered.)

The lecture part of the course needs no special equipment—a standard media-equipped classroom with a whiteboard, screen, and data projector should suffice. Having a portable laptop-connected oscilloscope would make demos much easier to do, but is not essential.

The lecture course is not really separable from the associated lab course,whose equipment needs are described on the supplemental sheet for that course.

The course requires a faculty member (simultaneously teaching the co-requisite Applied Circuits lab course) and a teaching assistant or undergraduate group tutor for discussion sections and assistance in grading.  The same TA/group tutor should be used for both the lecture and the lab courses.

8. If applicable, justify any pre-requisites or enrollment restrictions proposed for this course. For pre-requisites sponsored by other departments/programs, please provide evidence of consultation.

Students will be required to have single-variable calculus and a physics electricity and magnetism course. Both are standard prerequisites for any circuits course. Although DC circuits can be analyzed without calculus, differentiation and integration are fundamental to AC analysis. Students should have already been introduced to the ideas of capacitors and inductors and to serial and parallel circuits.

The prerequisite courses are already required courses for biology majors and bioengineering majors, so no additional impact on the courses is expected.

9. Proposals for new or revised Disciplinary Communication courses will be considered within the context of the approved DC plan for the relevant major(s). If applicable, please complete and submit the new proposal form (http://reg.ucsc.edu/forms/DC_statement_form.doc or http://reg.ucsc.edu/forms/DC_statement_form.pdf) or the revisions to approved plans form (http://reg.ucsc.edu/forms/DC_approval_revision.doc or http://reg.ucsc.edu/forms/DC_approval_revision.pdf).

This course is not expected to contribute to any major’s disciplinary communication requirement, though students will get extensive writing practice in the design reports (writing between 50 and 100 pages during the quarter).

10. If you are requesting a GE designation for the proposed course, please justify your request making reference to the attached guidelines.

No General Education code is proposed for this course, as all relevant codes will have already been satisfied by the prerequisites.

11. If this is a new course and you requesting a new GE, do you think an old GE designation(s) is also appropriate? (CEP would like to maintain as many old GE offerings as is possible for the time being.)

No General Education code is proposed for this course, as all relevant codes (old or new) will have already been satisfied by the prerequisites.

Lab course

Undergraduate Supplemental Sheet
Information to accompany Request for Course Approval
Sponsoring Agency Biomolecular Engineering
Course #
101L
Catalog Title
Applied Circuits Lab

Please answer all of the following questions using a separate sheet for your response.
1. Are you proposing a revision to an existing course? If so give the name, number, and GE designations (if applicable) currently held.

This is not a revision to any existing course. A prototype version of the course was run as BME 194F Group Tutorial in Winter 2013. Notes on the design and daily running of that prototype can be found at https://gasstationwithoutpumps.wordpress.com/circuits-course-table-of-contents

2. In concrete, substantive terms explain how the course will proceed. List the major topics to be covered, preferably by week.

The course is a lab course paired with BME 101, Applied Circuits for Bioengineers.  The labs have been designed to be relevant to bioengineers and to have as much design as is feasible in a first circuits course.  The labs are the core of the course, with lecture/discussion classes to support them. There will be six hours of lab a week, split into 2 3-hour sessions. Lab assignments will generally take two lab sessions, with data collection in the first lab session, and data analysis and design between lab sessions.   Some of the more straightforward labs will need only a single session.  Except for the first intro lab, these labs have been used in the prototype run of the class as 3-hour labs.  Most did not fit in one 3-hour lab session and would benefit from being split into two separate lab sessions with data analysis and design between the sessions.

  1. Intro to parts, tools, and lab equipment (single session)
  2. Thermistor
  3. Microphone
  4. Sampling and aliasing (single session)
  5. Audio amp
  6. Hysteresis oscillator and soldering lab
  7. FET and phototransistor
  8. Electrode modeling
  9. Pressure sensor and instrumentation amp (soldered)
  10. Class-D power amplifier
  11. EKG (instrumentation amp with filters, soldered)
  1. Intro to parts, tools, and lab equipment
    Students will learn about the test equipment by having them use the multimeters to measure other multimeters. What is the resistance of a multimeter that is measuring voltage? of one that is measuring current? what current or voltage is used for the resistance measurement? Students will be  issued their parts and tool kits, learn to use the wire strippers and make twisted-wire cables for the power supplies to use all quarter.  They will learn to set the current limits on the power supplies and  measure voltages and currents for resistor loads around 500Ω.  This lab will not require a written lab report.
    Lab skills developed: wire strippers, multimeter for measuring voltage and current, setting bench power supply
    Equipment needed: multimeter, power supply
  2. Thermistor lab
    The thermistor lab will have two lab sessions involving the use of a Vishay BC Components NTCLE413E2103F520L thermistor or equivalent.
For the first lab session, the students will use a bench multimeter to measure the resistance of the thermistor, dunking it in various water baths (with thermometers in them to measure the temperature). They should fit a simple curve to this data based on standard thermistor models. A class period will be spent on learning both the model and how to do model fitting with gnuplot, and there will be a between-lab exercise where they derive the formula for maximizing | dV/dT | in a voltage divider that converts the resistance to a voltage.
    For the scond lab session, they will add a series resistor to make a voltage divider. They have to choose a value to get as large and linear a voltage response as possible at some specified “most-interesting” temperature (perhaps body temperature, perhaps room temperature, perhaps DNA melting temperature).  They will then measure and plot the voltage output for another set of water baths. If they do it right, they should get a much more linear response than for their resistance measurements. 
Finally, they will hook up the voltage divider to an Arduino analog input and record a time series of a water bath cooling off (perhaps adding an ice cube to warm water to get a fast temperature change), and plot temperature as a function of time.
    Lab skills developed: use of multimeter for measuring resistance and voltage, use of Arduino with data-acquisition program to record a time series, fitting a model to data points, simple breadboarding.Equipment needed: multimeter, power supply, thermistor, selection of various resistors, breadboard, clip leads, thermoses for water baths, secondary containment tubs to avoid water spills in the electronics lab. Arduino boards will be part of the student-purchased lab kit. All uses of the Arduino board assume connection via USB cable to a desktop or laptop computer that has the data logger software that we will provide.
  3. Electret microphone
    First, we will have the students measure and plot the DC current vs. voltage for the microphone. The microphone is normally operated with a 3V drop across it, but can stand up to 10V, so they should be able to set the Agilent E3631A  bench power supply to various values from 0V to 10V and get the voltage and current readings directly from the bench supply, which has 4-place accuracy for both voltage and current. Ideally, they should see that the current is nearly constant as voltage is varied—nothing like a resistor.  They will follow up the hand measurements with automated measurements using the Arduino to measure the voltage across the mic and current through it for voltages up to about 4v.  The FET in the microphone shows a typical exponential I vs. V characteristic below threshold, and a gradually increasing current as voltage increases in the saturation region.  We’ll do plotting and model fitting in the data analysis class between the two labs.
    Second, we will have them do current-to-voltage conversion with a 5v power supply and a resistor to get a 1.5v DC output from the microphone and hook up the output of the microphone to the input of the oscilloscope. Input can be whistling, talking, iPod earpiece, … . They should learn the difference between AC-coupled and DC-coupled inputs to the scope, and how to set the horizontal and vertical scales of the scope. They will also design and wire their own DC blocking RC filter (going down to about 1Hz), and confirm that it has a similar effect to the AC coupling on the scope. Fourth, they will play sine waves from the function generator through a loudspeaker next to the mic, observe the voltage output with the scope, and measure the AC voltage with a multimeter, perhaps plotting output voltage as a function of frequency. Note: the specs for the electret mic show a fairly flat response from 50Hz to 3kHz, so most of what the students will see here is the poor response of a cheap speaker at low frequencies.
    EE concepts: current sources, AC vs DC, DC blocking by capacitors, RC time constant, sine waves, RMS voltage, properties varying with frequency.Lab skills: power supply, oscilloscope, function generator, RMS AC voltage measurement.Equipment needed: multimeter, oscilloscope, function generator, power supply, electret microphone, small loudspeaker, selection of various resistors, breadboard, clip leads.
  4. Sampling and Aliasing
    Students will use the data logger software on the Arduino to sample sine waves from a function generator at different sampling rates.  They will need to design a high-pass RC filter to shift the DC voltage from centered at 0 to centered at 2.5v in the middle of the Arduino A-to-D converter range.  They will also design a low-pass filter (with corner frequency below the Nyquist frequency) to see the effect of filtering on the aliasing.
    EE concepts: quantized time, quantized voltage, sampling frequency, Nyquist frequency, aliasing, RC filters.
    Equipment needed:  function generator, Arduino board, computer.
  5. Audio amplifier
    Students will use an op amp to build a simple non-inverting audio amplifier for an electret microphone, setting the gain to around 6 or 7. The amplifier will need a a high-pass filter to provide DC level shifting at the input to the amplifier. Note that we are using single-power-supply op amps, so they will have to design a bias voltage supply as well. The output of the amplifier will be recorded on the Arduino (providing another example of signal aliasing).
    The second half of the lab will add a single bipolar transistor to increase the current and make a class A output stage for the amplifier, as the op amp does not provide enough current to drive the 8Ω loudspeaker loudly.
    EE concepts: op amp, DC bias, bias source with unity-gain amplifier, AC coupling, gain computation.
    Lab skills: complicated breadboarding (enough wires to have problems with messy wiring). If we add the Arduino recording, we could get into interesting problems with buffer overrun if their sampling rate is higher than the Arduino’s USB link can handle.
    Equipment needed: breadboard, op amp chip, assorted resistors and capacitors, electret microphone, Arduino board, optional loudspeaker.
  6. Hysteresis and capacitive touch sensor
    For the first half of the lab, students will characterize a Schmitt trigger chip, determining VIL, VIH, VOL, and VOH. Using these properties, they will design an RC oscillator circuit with a specified period or pulse width (say 10μs), and measure the frequency and pulse width of the oscillator.
    For the second half of the lab, the students will build a relaxation oscillator whose frequency is dependent on the parasitic capacitance of a touch plate, which the students can make from Al foil and plastic food wrap. In addition to breadboarding, students will wire this circuit by soldering wires and components on a PC board designed for the oscillator circuit. Students will have to measure the frequency of the oscillator with and without the plate being touched. We will provide a simple Arduino program that is sensitive to changes in the pulse width of the oscillator and that turns an LED on or off, to turn the frequency change into an on/off switch.  Students will treat the oscillator board as a 4-terminal component, and examine the effect of adding resistors or capacitors between different terminals.
    EE concepts: frequency-dependent feedback, oscillator, RC time constants, parallel capacitors.
    Lab skills: soldering, frequency measurement with digital scope.
    Equipment needed: Power supply, multimeter, Arduino, clip leads, amplifier prototyping board, oscilloscope.
  7. Phototransistor and FET
    First half: characterize phototransistor in ambient light and shaded.  Characterize nFET and pFET.
    Second half: students will “tinker” with the components they have to produce a light-sensitive, noise-making toy.
    EE concepts: phototransistors, FETs.
    Equipment needed: breadboard, phototransistor, power FETs, loudspeaker, hysteresis oscillator from previous lab, oscilloscope.
  8. Electrode measurements
    First, we will have the students attempt to measure the resistance of a saline solution using a pair of stainless steel electrodes and a multimeter. This should fail, as the multimeter gradually charges the capacitance of the electrode/electrolyte interface.Second, the students will use a function generator driving a voltage divider with a load resistor in the range 10–100Ω. The students will measure the RMS voltage across the resistor and across the electrodes for different frequencies from 3Hz to 300kHz (the range of the AC measurements for the Agilent 34401A Multimeter). They will plot the magnitude of the impedance of the electrodes as a function of frequency and fit an R2+(R1||C1) model to the data, most likely using gnuplot. There will be a prelab exercise to set up plotting of the model and do a little hand tweaking of parameters to help them understand what each parameter changes about the curve.Third, the students will repeat the measurements and fits for different concentrations of NaCl, from 0.01M to 1M. Seeing what parameters change a lot and what parameters change only slightly should help them understand the physical basis for the electrical model.Fourth, students will make Ag/AgCl electrodes from fine silver wire. The two standard methods for this involve either soaking in chlorine bleach or electroplating. To reduce chemical hazards, we will use the electroplating method. As a prelab exercise, students will calculate the area of their electrodes and the recommended electroplating current.  In the lab, they will adjust the voltage on the bench supplies until they get the desired plating current.Fifth, the students will measure and plot the resistance of a pair of Ag/AgCl electrodes as a function of frequency (as with the stainless steel electrodes).Sixth, if there is time, students will measure the potential between a stainless steel electrode and an Ag/AgCl electrode.EE concepts: magnitude of impedance, series and parallel circuits, variation of parameters with frequency, limitations of R+(C||R) model.Electrochemistry concepts: At least a vague understanding of half-cell potentials, current density, Ag → Ag+ + e-, Ag+ + Cl- → AgCl, Fe + 2 Cl-→ FeCl2 + 2 e-.Lab skills: bench power supply, function generator, multimeter, fitting functions of complex numbers, handling liquids in proximity of electronic equipment.Equipment needed: multimeter, function generator, power supply, stainless steel electrode pairs, silver wires, frame for mounting silver wire, resistors, breadboard, clip leads, NaCl solutions in different concentrations, beakers for salt water, secondary containment tubs to avoid salt water spills in the electronics lab.
  9. Pressure sensor and instrumentation amplifier
    Students will design an instrumentation amplifier with a gain of 300 or 500 to amplify the differential strain-gauge signal from a medical-grade pressure sensor (the Freescale MPX2300DT1), to make a signal large enough to be read with the Arduino A/D converter. The circuit will be soldered on the instrumentation amp/op amp protoboard. The sensor calibration will be checked with water depth in a small reservoir. Note: the pressure sensor comes in a package that exposes the wire bonds and is too delicate for student assembly by novice solderers. We will make a sensor module that protects the sensor and mounts the sensor side to a 3/4″ PVC male-threaded plug, so that it can be easily incorporated into a reservoir, and mounts the electronic side on a PC board with screw terminals for connecting to student circuits.  This sensor is currently being prototyped, and if it turns out to be too fragile, we will use a Freescale MPX2050GP, which has a sturdier package, but is slightly less sensitive and more expensive. (It also isn’t made of medical-grade plastics, but that is not important for this lab.) Note that we are deliberately notusing pressure sensors with integrated amplifiers, as the pedagogical point of this lab is to learn about instrumentation amplifiers.EE concepts: differential signals, twisted-pair wiring, strain gauge bridges, instrumentation amplifier, DC coupling, gain.Equipment needed: Power supply, amplifier prototyping board, oscilloscope, pressure sensor mounted in PVC plug with breakout board for easy connection, water reservoir made of PVC pipe, secondary containment tub to avoid water spills in electronics lab.
  10. Class-D power amplifier
  11. Electrocardiogram (EKG)
    Students will design and solder an instrumentation amplifier with a gain of 2000 and bandpass of about 0.1Hz to 100Hz. The amplifier will be used with 3 disposable EKG electrodes to display EKG signals on the oscilloscope and record them on the Arduino.Equipment needed: Instrumentation amplifier protoboard, EKG electrodes, alligator clips, Arduino, oscilloscope.

3. Systemwide Senate Regulation 760 specifies that 1 academic credit corresponds to 3 hours of work per week for the student in a 10-week quarter. Please briefly explain how the course will lead to sufficient work with reference to e.g., lectures, sections, amount of homework, field trips, etc. [Please note that if significant changes are proposed to the format of the course after its initial approval, you will need to submit new course approval paperwork to answer this question in light of the new course format.]

The combination of BME101 and BME101L is 7 units (21 hours per week).  The time will be spent approximately as follows:

  • 3.5 hours lecture/discussion
  • 3.5 hours reading background and circuits text
  • 3 hours read lab handouts and doing pre-lab design activities
  • 6 hours lab
  • 5 hours writing design reports for lab

4. Include a complete reading list or its equivalent in other media.

Lab handouts: there is a 5- to 10-page handout for each week’s labs, giving background material and design goals for the lab, usually with a pre-lab design exercise.  The handouts from the prototype run of the course can be found at http://users.soe.ucsc.edu/~karplus/bme194/w13/#labs
Data sheets: Students will be required to find and read data sheets for each of the components that they use in the lab.  All components are current commodity components, and so have data sheets easily found on the web.  Other readings are associated with the lecture course.

5. State the basis on which evaluation of individual students’ achievements in this course will be made by the instructor (e.g., class participation, examinations, papers, projects).

Students will be evaluated on in-lab demonstrations of skills (including functional designs) and on the weekly lab write-ups.

6. List other UCSC courses covering similar material, if known.

CMPE 167/L (sensors and sensing technologies) covers some of the same sensors and design methods, but at a more advanced level.  BME 101L would be excellent preparation for the CMPE 167/L course.

Physics 160 offers a similar level of practical electronics, but focuses on physics applications, rather than on bioengineering applications, and is only offered in alternate years.

7. List expected resource requirements including course support and specialized facilities or equipment for divisional review. (This information must also be reported to the scheduling office each quarter the course is offered.)

The course will need the equipment of a standard analog electronics teaching lab: power supply, multimeter, function generator,  oscilloscope,  computer, and soldering irons. The equipment in Baskin Engineering 150 (commonly used for EE 101L) is ideally suited for this lab. There are 12 stations in the lab, providing a capacity of 24 students since they work in pairs rather than as individuals.  The only things missing from the lab stations are soldering irons and circuit board holders (such as the Panavise Jr.), a cost of about $45 per station.  Given that a cohort of bioengineering students is currently about 35–40 students, two lab sections would have to be offered each year.

In addition, a few special-purpose setups will be needed for some of the labs, but all this equipment has already been constructed for the prototype run of the course.

There are a number of consumable parts used for the labs (integrated circuits, resistors, capacitors, PC boards, wire, and so forth), but these are easily covered by standard School of Engineering lab fees.  The currently approved lab fee is about $131, but may need some adjustment to change exactly what tools and parts are included, particularly if the students are required to buy their own soldering irons (a $20 increase).

The course requires a faculty member (simultaneously teaching the co-requisite Applied Circuits course) and a teaching assistant (for providing help in the labs and for evaluating student lab demonstrations). Because the lab is such a core part of the combined course, it requires faculty presence in the lab, not just coverage by TAs or group tutors.

8. If applicable, justify any pre-requisites or enrollment restrictions proposed for this course. For pre-requisites sponsored by other departments/programs, please provide evidence of consultation.

Students will be required to have single-variable calculus and a physics electricity and magnetism course. Both are standard prerequisites for any circuits course. Most of the labs can be done without calculus, but it is essential for the accompanying lecture course.

9. Proposals for new or revised Disciplinary Communication courses will be considered within the context of the approved DC plan for the relevant major(s). If applicable, please complete and submit the new proposal form (http://reg.ucsc.edu/forms/DC_statement_form.doc or http://reg.ucsc.edu/forms/DC_statement_form.pdf) or the revisions to approved plans form (http://reg.ucsc.edu/forms/DC_approval_revision.doc or http://reg.ucsc.edu/forms/DC_approval_revision.pdf).

This course is not expected to contribute to any major’s disciplinary communication requirement, though students will get extensive writing practice in the design reports (writing between 50 and 100 pages during the quarter).

10. If you are requesting a GE designation for the proposed course, please justify your request making reference to the attached guidelines.

No General Education code is proposed for this course, as all relevant codes will have already been satisfied by the prerequisites.

11. If this is a new course and you requesting a new GE, do you think an old GE designation(s) is also appropriate? (CEP would like to maintain as many old GE offerings as is possible for the time being.)

No General Education code is proposed for this course, as all relevant codes (old or new) will have already been satisfied by the prerequisites.


Filed under: Circuits course Tagged: bioengineering, capacitive touch sensor, circuits, course design, ECG, EKG, electret mic, electret microphone, electrocardiogram, electrodes, electronics, op amp, phototransistor, pressure sensor, sensors, teaching, thermistor

Viewing all articles
Browse latest Browse all 68

Trending Articles